Most of the company's products can provide a full range of customized services including product materials, models, functions, packaging. Please contact customer service staff for details.
Through more than ten years of medical and health product export services, we have accumulated a wealth of industry experience, and can provide professional and personalized services to meet the needs of different customers around the world for personalized and branded customized medical products.
| Type: | HIV 1/2 Antibody Rapid Test Kit (Cassette/Strip) | Brand Name: | HIPROVE |
| Origin: | China | Model NO.: | QS2 |
| Package: | 1 pc/bag, 20 pcs/box | Function: | HIV-1/HIV-2 Antibody IVD Auxiliary Screening |
| Customization: | Available (OEM/ODM) | Material: | Plastic/Paper |
| Sterilization: | Ethylene Oxide Sterilization | Shelf Life: | 3 Years |
| Logo Printing: | Customized | Group: | All |
| Specification: | 2.5-6mm | Test Format: | Cassette/Strip |
| Specimen: | Whole Blood/Serum/Plasma | Application: | AIDS Auxiliary Diagnosis |
| Certificates: | CE/ISO | Usage: | Hospital Clinical & Home Use |
| Sample: | Sample Offered | Production Capacity: | 50000 pcs/day |
One Step HIV 1/2 Antibody Rapid Test Kit (Cassette/Strip, Whole Blood/Serum/Plasma, QS2)
【Product Overview】
This is a one step HIV 1/2 antibody rapid test kit that uses whole blood, serum or plasma to quickly screen for infection with human immunodeficiency virus (HIV-1/HIV-2). It is available in cassette and strip formats, with results in about 20 minutes, suitable for hospitals, clinics, health checks and home screening.

【Product Highlights】
· Factory Direct Supply: manufactured by an IVD reagent producer, CE/ISO certified and ethylene oxide sterilised, suitable for importers and distributors;
· Two Formats: available as test cassette and test strip to meet different end-user and budget needs;
· Three Specimen Types: whole blood, serum and plasma all supported, fitting hospital laboratories and field screening workflows;
· Fast and Visual: results in about 20 minutes, read by eye with no complex instruments;
· Reliable Supply Capacity: production capacity of 50000 pcs/day, supporting bulk orders and continuous replenishment;
· Customisation Available: OEM/ODM private labelling and custom logo, with sample support for global markets;
· Standard Packaging: 1 pc/individual foil pouch, 20 pcs/box, 3-year shelf life for easy storage and distribution.


【Test Principle】
This test uses an immunochromatographic (double antigen sandwich) assay. The test line (T) is pre-coated with HIV-specific recombinant antigen and colloidal gold is conjugated with another HIV antigen. When HIV-1 or HIV-2 antibodies are present in the sample, they bind to the gold-labelled antigen and are captured by the immobilised antigen at the T line, producing a visible band. The control line (C) captures labelled antigen to indicate a valid test. A visible C line confirms a valid test regardless of whether antibodies are present.
【Specimen】
Human whole blood, serum or plasma. Per the insert: for whole blood add 1 drop (about 20-30 µL) to the sample well followed by 1-2 drops of buffer; for serum/plasma add 2-3 drops. Avoid grossly haemolysed, lipaemic or repeatedly frozen-thawed samples. Test as soon as possible; store at 2-30°C and do not freeze.
【Operation (Summary)】
1. Equilibrate reagents and samples to room temperature before testing;
2. Open the foil pouch, remove the cassette (or strip), place it flat on a clean surface and label it;
3. Add the specified number of drops of sample to the well (add buffer for cassettes) as described above and start the timer;
4. Wait for bands to appear and read within about 20 minutes; results read later are invalid.
【Result Interpretation】
Reactive (positive): both C and T lines appear, suggesting HIV antibodies may be present;
Non-reactive (negative): only the C line appears and no T line, indicating no HIV antibodies detected;
Invalid: no C line appears, indicating incorrect procedure or a faulty device — repeat with a new device.
Any reactive result is a screening indication only and must be confirmed by a professional facility (e.g. Western Blot, line immunoassay or nucleic acid testing) before a diagnosis is made.
【Package & Storage】
1 pc/foil pouch, 20 pcs/box; store at 2-30°C protected from light and moisture, do not freeze. Shelf life 3 years. Production capacity 50000 pcs/day; confirm the exact delivery time with the supplier.
【Important Notes】
1. For in vitro screening only — not a stand-alone diagnosis; reactive results require confirmatory testing at a professional facility;
2. A window period exists (antibodies usually become detectable about 2-6 weeks after infection), so testing during the window period may give a false negative; retest after the window period if there has been recent high-risk exposure;
3. This is a qualitative test and does not reflect viral load or infection stage; the intensity of the T line does not indicate disease severity;
4. Rare false positives or negatives may occur; interpret results together with epidemiological history, clinical symptoms and other laboratory findings;
5. Single use only; do not use expired, damaged or damp devices; use personal protection and dispose of samples and waste as medical waste.